AC Power adapter (12V, 16A, 192W) [http://www.cartft.com/catalog/il/2777] |
64.95 EUR
incl. 19% VAT, plus shipping
|
Model | Output Voltage | Output Current | Watt |
---|---|---|---|
STD-12160 | 12.0V | 16.0A | 192W |
Input | |||
Voltage | 100-240 VAC | ||
Line Frequency | 50-60Hz | ||
Current | 2.8A Max. | ||
Protection | Internal Primary Current Fuse | ||
Configuration | IEC60320 / C14 | ||
Output | |||
Load Regulation | ± 5% (Typical) | ||
Ripple | 3~5% Vp-p Max. for Output Voltage @ Full Load | ||
Transient Response | 0.5mS for 50% Load Change Typical | ||
Holdup Time | 10mS @ Full Load | ||
Protection | Short Circuit Protection/ Over Voltage Protection/ Over Current Protection/Over Temperature Protection |
||
DC Cord | UL2464 / 16AWG | ||
Ferrite Core | No (Optional) | ||
Safety Approvals | |||
CB / UL / cUL / FCC / GS / CE / PSE / BSMI / CCC / RCM | |||
Electrical | |||
Topology | LLC | ||
Dielectric Withstand | 3,000 VAC Primary – Secondary | ||
Leakage Current | 3.5mA @ 3 Pin | ||
Efficiency | Engergy Star Level V, ErP Stage 2 & NRCan Certified | ||
EMI Conduction&Radiation | Compliance to EN55022 Class B | ||
Harmonic Current | Compliance to EN61000-3-2,3 | ||
EMS Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11 | ||
MTBF | 300,000 Calculated Hours at 25°C, by Telcordia SR-332 | ||
Environmental | |||
Operaturing Temperature | 0 to +40°C | ||
Storage Temperature | -20 to +80°C | ||
Relative Humidity | Operating: 20 to 80% RH | ||
Storage: 10 to 90% RH | |||
Cooling | Natural Convection Cooling | ||
Mechanical | |||
Case Dimension | L183 x W81 x H42 (mm) | ||
Weight | 850g (Ref.) |